    CSH7573-70Y 70HP Walk In Chiller Cooling Unit Stable Operation Chiller Unit


    Product Description

    Chiller unit is a type of water cooling equipment that can provide constant temperature, constant flow, and constant pressure cooling water. Inject a certain amount of water into the internal water tank in advance, cool the water through the refrigeration system of the chiller, and then send the low-temperature cooling water to the equipment that needs to be cooled by the water pump. The chilled water of the chiller takes away the heat, increases the temperature, and then flows back to the water tank to achieve cooling.





    Model

    CSH7573-70Y

    Horse Power

    70HP

    Power(kW)

    440V/3P/60Hz

    Refrigerant

    R134a

    Cooling Method

    Water-Cooling

    Outlet/Return Water Temperature

    7/12℃

    Evaporating Temperature

    2℃

    Condensing Temperature

    40℃

    Refrigeration Capacity

    178.6kW

    153.6(103kcal/hr)

    Overall Size

    2800*1100*1430mm

    Noise Value

    66dB(A)

    Overall Weight

    1470kg

    Operating Weight

    1800kg

    Compressor

    Input Power

    43.1kW

    Operating Current

    64.5A

    Capacity Control

    25%-50%-75%-100%

    Condenser

    Water Pipe Connection

    DN100mm

    Water Flow

    38m³/h

    Water Pressure Drop

    41kPa

    Evaporator

    Water Pipe Connection

    DN80mm

    Water Flow

    31m³/h

    Water Pressure Drop

    39kPa

    Product Category :

    1.Double Stage series Inlet water temperature : -50°C~-35°C; outlet water temperature: -55°C~-40°C 

    2.Low temperature series Water inlet temperature : -35°C~-10°C; outlet water temperature: -40°C~-15°C 

    3.High temperature series Inlet water temperature : -15℃~12℃; outlet water temperature: -20℃~7℃





    Product Display


    Application scope

    Electronic industry: Stabilize the molecular structure of electronic components on the production line, improve the qualification rate of electronic components, and apply it to the ultrasonic cleaning industry to effectively prevent the volatilization of expensive cleaning agents and the harm they cause to people.

    Mechanical industry: Control the pressure and temperature of the oil pressure system, stabilize the oil temperature and pressure, extend the service life of the oil quality, improve the efficiency of mechanical lubrication, and reduce wear.

    Construction industry: providing chilled water for concrete, making the molecular structure of concrete suitable for building purposes, effectively enhancing the hardness and toughness of concrete.

    Food industry: used for high-speed cooling after food processing to meet packaging requirements. In addition, there are also temperature control measures for fermented food.


    Our Factory


    1.Xiamen Jialiang series screw compressor racks are assembled with original semi-hermetic screw compressors;

    2.Specially used for low temperature application and big capacity demand; 

    3.With development of refrigeration market, huge capacity cold rooms are required, screw compressor rack is perfectly applicable for it; 

    4.The racks are with protect function of overheat, overload, exhaust temperature , low oil level, oil flow; 

    5.Famous band screw compressor rack for refrigeration system is the most popular equipment, which is welcome by many customers.






    FAQ

    A1: Can I customize the chiller unit?

    Q2: Yes. You can choose output, material, accessories brand, etc.

    A2: What is the refrigeration capacity of the evaporator and the heat exchange capacity of the condenser?

    Q2: Evaporator cooling capacity 196.46kw, condenser exchange capacity 222kw

    A3: How much oil and refrigerant are prepared?

    Q3: For each machine in this order, 10 liters of refrigerant oil and 60KG of Freon will be prepared.


    Contact Us


    Related Condensing Unit
    Contact Us
    • Name: *
    • Email: *
    • Skype/WhatsApp/Tel: *
    • Country: *
    • Details: *
    JiaLiang Blog

    we have experienced projects all over the world and provide trustworthy solution services to meet customers' need.

    • 14
      Jul
    • Comparison And Selection Between Solar Cold Room And Ordinary Cold Room
    • Solar-powered cold storage and conventional cold storage each have their pros and cons, suited to different usage scenarios: As a new energy-efficient cold chain storage solution, solar-powered cold storage aligns with the trend of low-carbon development and can address refrigeration needs in remote areas without electricity, but it requires high upfront investment and is affected by weather conditions in terms of stability. Conventional cold storage, with its mature technology, low cost, and stable power supply, remains the mainstream choice in the current market, but it entails high long-term operating costs, significant carbon emissions, and limited application scenarios. In practical applications, there is no absolute superiority or inferiority—only by considering factors such as site conditions, budget scale, and operational requirements can the most suitable cold storage type be selected.
    • -Read More
    • 06
      Jul
    • Design and Application Scenarios of Ice Cold Storage
    • Ice cold storage is a specialized low-temperature cold storage used for storing ice cubes. Its core requirement is to maintain a stable low-temperature environment to avoid ice melting and loss. It can be built to different scales according to demand and adapted to different ice usage needs in different scenarios. It widely serves multiple fields such as food preservation supply, ice storage cold chain logistics, industrial production, engineering cooling, etc. It can balance the seasonal and off peak differences in ice production and demand, and stably guarantee the supply of ice sources. In the design and construction process, it is necessary to focus on five core tasks: thermal insulation of the warehouse body, matching of refrigeration unit power, safe operation, construction of drainage system, and temperature monitoring, in order to ensure the long-term stable operation of the ice cold storage and meet the needs of long-term ice storage.
    • -Read More
    • 18
      Jun
    • Solar Powered Cold Storage: A Green New Choice For Agricultural Fresh Food Preservation
    • Over the past few decades, solar-powered cold storage has gone through invention, development, and maturation, standing the test of the market. In the current situation of energy scarcity and increased environmental awareness, it has gradually become the first choice for purchasing cold storage. Its advantages are evident:
    • -Read More
    Ok